-
Tren Ace 100mg - 2nd Homebrew
For this batch I followed almost the exact same steps as I did with the Primo E. The only MAJOR difference was the temperature I heated the mixture to. I didn't want to get this to hot.
Recipe:
Recipe.jpg
Equipment:
- 500 ml Beaker
- 60 ml sterile luer lock syringes (2)
- 3 ml syringe w/25 gauge needle
- 18 gauge needles
- Benzyl Benzoate, Benzyl Alcohol
- 99% isopropyl alcohol
- Hair net
- Nitrile gloves
- Alcohol wipes
- 10ml sterile sealed vials
- Autofil vacuum bottle top filter with .22 micron filter.
- Vacuum hand pump
- Glass thermometer / stirrer
- Skillet
- Stove Top
- Clorox cleaning wipes
Procedure:
- Sterilize counter space, stove top, working area with clorox cleaning wipes.
- Sterilize beaker with isopropyl alcohol - let dry.
- Fill skillet with approx 1.5 inches water and bring to slow boil.
- Add 10g Tren Ace raw powder to beaker and add Benzyl Benzoate (used first 60 ml syringe for this, I will save this syringe for use in future cooks), gently swirl until almost dissolved.
- Place beaker in skillet in water bath swirl. Raws will dissolve completely.
- Add MCT Oil to mixture, stir gently, checking temp.
- I heated the solution for approximately 30 minutes at around 150 degrees F.
- Remove from heat and add Benzyl Alcohol (used 3ml syringe for this).
- Mix well and let cool to 90 degrees F. (covered loosely with aluminum foil)
- Pour warm solution into Autofil bottle top vacuum filter, place lid on top, attach hand pump, pump to 300 mm/hg, and wait. As pressure drops to around 150 mm/hg, repump to 300. Repeat until solution is all filtered (took about 30 minutes).
- *THE NEXT STEP IS NOT IDEAL - I HAVE ANOTHER METHOD FOR NEXT TIME BUT, WITH PRECAUTIONS, THIS METHOD WORKS*: In my clean kitchen with no fans, carpet, rugs, hair net on, gloves on - remove plunger from sterile 60ml syringe with fresh 18 gauge needle attached and capped. Remove top of Autofil and quickly pour finished oil in syringe (backfill).
- Sterile sealed vials are already wiped with alcohol swab and first one has 18 gauge needle inserted to vent.
- Uncap needle attached to 60 ml syringe containing finished oil, insert into vial. Slowly install plunger back into syringe and fill vials.
- DONE!
20180816_214112.jpg
20180816_223129.jpg
-
Post Thanks / Like - 2 Thanks, 3 Likes, 0 Dislikes
----
-
-
Post Thanks / Like - 1 Thanks, 4 Likes, 0 Dislikes
----
-
Liquid gold brother! Looking to start my first brew. Want to do test e and primo e. Inspiration right here! Mind if I pm to ask a few questions?
Sent from my iPhone using Tapatalk
-
Post Thanks / Like - 2 Thanks, 1 Likes, 0 Dislikes
----
-
Originally Posted by
Lvndead
Liquid gold brother! Looking to start my first brew. Want to do test e and primo e. Inspiration right here! Mind if I pm to ask a few questions?
Sent from my iPhone using Tapatalk
I'm no expert, just a novice. However, feel free to pm me.
Sent from my SM-N950U using Tapatalk
----
-
i will not use a 60 ml syringe for measuring my ba or bb cause they can be way off you be better of with 10 ml or a class a measuring cylinder beside that thanks for the post
-
Post Thanks / Like - 1 Thanks, 2 Likes, 0 Dislikes
----
-
looks nice did you pin it ?
A great man once said, everything is about sex. Except sex. Sex is about power.
----
-
Originally Posted by
Indahood
looks nice did you pin it ?
Sure did. Nice and smooth. Now it is put away for a future blast.
Sent from my SM-N950U using Tapatalk
-
Post Thanks / Like - 0 Thanks, 1 Likes, 0 Dislikes
----
-
I like the labels.
Did the plastic bottle crack?
----
-
Originally Posted by
THX
I like the labels.
Did the plastic bottle crack?
Thanks. I just used a Dymo label maker from work. Lol.
I don't know why everyone is asking if the plastic cracked. What are these folks using for vacuum pumps? I can't see how a hand pump, pumped to a pressure of 300-350 mm/hg could cause these things to implode. It takes a little while to filter it, but I would rather wait 30 minutes or so than pump that sonofabitch up so hard I break my pump or crack my Autofil.
Sent from my SM-N950U using Tapatalk
----
-
I use electrical vacuum pump it always cracks, I was using gl45 and now finally whole glass filteration system..
A great man once said, everything is about sex. Except sex. Sex is about power.
----
Bookmarks