Transferring oil from media bottle to vials
What are you guys using to transfer the oil from media bottles to the open vials? Once I pull the top mount filter off the media bottle I知 just drawing out using 5ml syringe but takes a bit and seems unsterile. Looking for a better option.
Sent from my iPhone using Tapatalk
-
Post Thanks / Like - 1 Thanks, 1 Likes, 0 Dislikes
----
-
Originally Posted by
jsnm
What are you guys using to transfer the oil from media bottles to the open vials? Once I pull the top mount filter off the media bottle I知 just drawing out using 5ml syringe but takes a bit and seems unsterile. Looking for a better option.
Sent from my iPhone using Tapatalk
Hey bud I sent you a pm
Sent from my SM-J337V using Tapatalk
-
Post Thanks / Like - 1 Thanks, 1 Likes, 0 Dislikes
jsnm thanked for this post
jsnm liked this post
----
-
Originally Posted by
jsnm
What are you guys using to transfer the oil from media bottles to the open vials? Once I pull the top mount filter off the media bottle I知 just drawing out using 5ml syringe but takes a bit and seems unsterile. Looking for a better option.
Sent from my iPhone using Tapatalk
I would be interested in hearing from some folks on this. I do what you do but with a 10ml syringe.
Sent from my Galaxy Note 9 using Tapatalk
-
Post Thanks / Like - 0 Thanks, 1 Likes, 0 Dislikes
jsnm liked this post
----
-
A very simple solution is to use the pour rings that come with the media bottles. You know, the thin plastic thing you forgot to take off bottle before "sterilizing" in the oven and it melted. It takes a steady hand but is easy enough, except from liter bottles.
I first used 30 or 60cc syringes you can get from the veterinary supply.
If you use a peristaltic pump for filtering, you can set that up to dispense IF you autoclave the silicone tubing.
I got a Brandtech Handistep digital pipette for just over $100 on eBay. They are about $1200 new. Slow but absolutely precise and the motor does everything.
I recently got a cool bottle top dispenser for about $300 on eBay as well but haven't used it yet. The whole device is autoclavable.
-
Post Thanks / Like - 1 Thanks, 1 Likes, 0 Dislikes
jsnm thanked for this post
jsnm liked this post
----
-
-
Post Thanks / Like - 1 Thanks, 1 Likes, 0 Dislikes
jsnm thanked for this post
jsnm liked this post
----
-
So I realized also they have the open caps for the gl45 media bottle with the septa rubber caps suitable for drawing the oil out with a syringe. Has anyone tried this method? Seems to be a pretty sterile option.
Sent from my iPhone using Tapatalk
----
-
I use a 60 ml syringe with a metal tip, to extract and fill.
----
-
I guess it depends on how much volume your going through.
Personal usage I would think a 20ml syringe should be good enough.
If you doing heavy volume than I would go with a bottle top dispenser. Well worth the money if your doing lots or volume.
----
-
What is a media bottle? Also i get Dr prescribed TRT. Does it hurt anything if i refill the ml bottles with ugl test after its gone in case i travel or soething?
----
-
Originally Posted by
bulldogger
What is a media bottle? Also i get Dr prescribed TRT. Does it hurt anything if i refill the ml bottles with ugl test after its gone in case i travel or soething?
Reusing bottles without sterilizing and then capping with new sterile caps, is a recipe for killing yourself. Don稚 do that.
Sent from my iPhone using Tapatalk
----